Chapter 2 Quick Start
To use the power supply in constant voltage mode
30
5 Adjust the knob for the desired current limit.
1
Check that the Lmt annunciator still blinks. Set the knob for current control.
The second digit of ammeter will be blinking. Adjust the knob to the desired
current limit.
6 Adjust the knob for the desired output voltage.
1
Set the knob for voltage control. The second digit of the voltmeter will be
blinking. Adjust the knob to the desired output voltage.
7 Return to the meter mode.
key or let the display time-out after several seconds to return
to the meter mode. Notice that the Lmt annunciator turns off and the display
returns to the meter mode. In the meter mode, the display shows the actual
output voltage and current of the selected supply.
8 Verify that the power supply is in the constant voltage mode.
If you operate the +6V supply in the constant voltage (CV) mode, verify that
CV and +6V annunciators are lit. If you operate the power supply for +25V
supply or -25V supply, the +25V or -25V annunciator will turn on. If the CC
annunciator is lit, choose a higher current limit.
Note
During actual CV operation, if a load change causes the current limit to be
exceeded, the power supply will automatically crossover to constant current
mode at the preset current limit and the output voltage will drop
proportionately.
1
You can use the resolution selection keys to move the blinking digit to the right or
left when setting the voltage and current.
Vol/Cur
Vol/Cur
Display Limit
Display Limit