of 20
 
10
Recharge the A/C System
1
PressCHARGE Opentheappropriatepanelvalve(s),
dependingonwherethesystemshouldbecharged–
high-side,low-side,orboth
2 Press
CHARGE
againtochangetheunitsof
measureAcceptthedefaultweightbypressing
START / YES,orusethearrowkeystoscrolltothe
correctamount,andpressSTART / YES
3
Thedisplayreads
CHARGEINPROGRESS/DONOTDISTURB
XXXLBS(XXXKG)
Movingorbumpingtheunitatthispointmayresult
inanincorrectreading
Note:
During a charge cycle, if the unit fails to transfer
refrigerant due to low tank pressure, the charge
process is automatically interrupted and the unit
operates in a mode to build tank pressure. Once
tank pressure is sufcient, the unit automatically
completes the charge.
When the charge cycle gets close to the weight
entered in Step 2, the unit slows down. It’ll charge,
settle, charge again, settle, etc.
4Whenthechargeiscomplete,thedisplayreads
CHARGEDXXXLBS(KG)
PRESSSTARTTOEQUALIZEHOSES
Theusermustequalizepressureintheservicehoses
toensureallliquidrefrigeranttrappedinthehosesis
transferredtothevehicleA/Csystemforanaccurate
chargePressSTART / YEStoequalizehoses
5 Closethehigh-sidecouplervalveThedisplayreads
DISCONNECTHSHOSE
OPENPANELVALVES
ANDSTARTA/CMAX
STARTTOCONTINUE
Thehigh-sidehosemustberemovedfromthe
vehicle,andthe low-side hose must stay
connected to the vehiclewiththelow-side
coupleropen
6 Openbothpanelvalves
Operating Instructions
Operating Tips
After selecting the CHARGE function and
entering a desired weight, if the weight
entered will leave less than 2 lbs. (.91 kg) of
refrigerant in the internal tank after charge,
the charge function will not start. The display
reads
INSUFFICIENTREFRIG
PRESSANYKEYTOEXIT
Refer to the Maintenance section of this
manual for instructions to Manually Rell the
Internal Storage Vessel (ISV).