0

Out of 0 Ratings

Owner's of the RobinAir Air Compressor Recovery, Recycling, Recharging Unit gave it a score of 0 out of 5. Here's how the scores stacked up:
  • Reliability

    0 out of 5
  • Durability

    0 out of 5
  • Maintenance

    0 out of 5
  • Performance

    0 out of 5
  • Ease of Use

    0 out of 5
of 20
 
8
Operating Instructions
Recover Refrigerant from a Vehicle
1 Emptytheoildrainbottlelocatedontheright-hand
sideoftheunit,ifnecessary,ormakenoteofthe
currentoillevelSeeFigure5
2 Connectthehigh-andlow-sidehosestothevehicle
A/Csystem
3 Openthecouplervalvesonthehoses
4 Openthehigh-andlow-sidepanelvalvesonthe
controlpanel
5 PresstheRECOVERbutton
Note: The clicking noise heard during the recovery
process indicates the solenoid is opening and closing —
this is normal.
6 Whenthesystemhasrecoveredto0psi,thevacuum
pumpstartsandrunsuntilrecoveryiscompleteThe
unitthengoesintoanautomaticoildrain—thismay
require90secondstocomplete
7 Aftertheoildrainiscomplete,thedisplayshows
RECOVERCOMPLETE
RECOVEREDXXXXLBS(XXXKG)
CHECKOILBOTTLE
Note: The displayed recovered weight can vary,
depending on ambient conditions, and should not be
used as an indicator of scale accuracy.
8 Checktheoildrainbottle,andnotetheamountofoil
thatwasremovedfromtheA/CsystemThisisthe
amountofnewoilthatmustbechargedintotheA/C
systemafterevacuationiscomplete
• Useonlynewoiltoreplacetheoilremovedduring
therecyclingprocess
• Disposeofusedoilaccordingtolocal,state,and
federalregulations
RecoveryiscompleteYouarenowreadytoeither
advancetothechargeprocess,ortomakerepairstothe
A/Csystemfollowedbytheevacuationprocess
Oil Drain
Bottle
Figure 5
Operating Tips
After the RECOVER function is selected :
If system pressure is below 10 psi, the display
reads
LOWRECOVERPRESSURE
CHECKCONNECTIONS
until pressure increases, or the START / YES
button is pressed. Verify the high- and low-side
hoses are connected and coupler valves are
open. Press STOP / NO to exit.
• If 100 lbs. (45 kg) or more of refrigerant has
been recovered since the last lter-drier change,
the display reads
FILTERWEIGHTXXXLB(XXKG)
To meet SAE J-2788 requirements, it is
mandatory to replace the lter-drier after
150 lbs. (68 kg) of refrigerant has been
ltered.
The unit gives a warning to replace
the lter when lter weight reaches 100 lbs.;
when lter weight reaches 150 lbs., the unit
locks out and ceases to operate.
Refer to
instructions outlined in the Maintenance section
under Replace the Filter-Drier.