0

Out of 0 Ratings

Owner's of the Genie Wheelchair Genie gave it a score of 0 out of 5. Here's how the scores stacked up:
  • Reliability

    0 out of 5
  • Durability

    0 out of 5
  • Maintenance

    0 out of 5
  • Performance

    0 out of 5
  • Ease of Use

    0 out of 5
of 38
 
Operator's Manual
Third Edition • Second Printing
Part No. 97779 GR-12 • GR-15 • GR-20 25
Battery and Charger Instructions
Observe and Obey:
Do not use an external charger or booster
battery.
Charge the battery in a well-ventilated area.
Use proper AC input voltage for charging as
indicated on the machine.
Use only a Genie authorized battery and
charger.
To Charge Batteries
Maintenance - free batteries
1 Connect the battery charger to a grounded AC
circuit.
2 The charger will indicate when the battery is fully
charged.
OPERATING INSTRUCTIONS
Standard Batteries
1 Put on protective clothing and eye wear.
2 Raise the platform approximately 1.5 m.
3 Open the battery cover. Rest the cover against
the chassis.
4 Lower the platform until the mast just contacts
the battery cover.
Crushing hazard. Keep hands clear
of the battery cover when lowering
the platform.
5 Turn the key switch to the off position.
6 Be sure that the battery cable connections are
tight and free of corrosion.
7 Remove the battery vent caps and check the
battery acid level. If necessary, add only
enough distilled water to cover the plates. Do
not overfill prior to the charge cycle.
8 Replace the battery vent caps.
9 Connect the battery charger to a grounded AC
circuit.
10 The charger will indicate when the battery is fully
charged.
11 Check the battery acid level when the charging
cycle is complete. Replenish with distilled water
to the bottom of the fill tube. Do not overfill.
12 Raise the platform and lower the cover.