0

Out of 0 Ratings

Owner's of the First Alert Security Camera First Alert Security Camera gave it a score of 0 out of 5. Here's how the scores stacked up:
  • Reliability

    0 out of 5
  • Durability

    0 out of 5
  • Maintenance

    0 out of 5
  • Performance

    0 out of 5
  • Ease of Use

    0 out of 5
of 24
 
Page 13
Alarm Inputs:
Alarm inputs are switches that activate when a
door, window, cabinet etc. is opened or accessed.
For example, you might want to only have the
camera record when someone opens a tool cabinet
or when a door opens vs. recording when motion
occurs around those areas. There may be people
moving by those areas frequently but you are only
concerned about when those areas are accessed.
This saves storage space and makes it easier to
find an event that was recorded.
External Sensor Alarm Pattern:
5 Seconds ON 3 Seconds OFF repeat...
Motion Alarm Pattern:
2 seconds on
NOTE: The Maximum output current is 300mA and the
Maximum Output voltage is 5.0V.
NOTE: When using external sensor you must program the
view location on program 2. When external sensor is tripped
the camera will move to the preset location.
To Connect an external Sensor
to the DWIP-720
Connect GND (-) of Sensor to ALARM IN 4(-) of the DWIP-720.
Connect NO (+) of Sensor to ALARM IN 3(+) of the DWIP-720.
To Connect an external Alarm
to the DWIP-720
Alarm output is used to activate an external device such as
a horn or LED or relay after an alarm is triggered. To configure
alarm outputs, connect the external device to the out
connections on the alarm block as required by the device.
Connect (-) of ALARM to ALARM IN 2(+) of the DWIP-720.
Connect (+) of ALARM to ALARM IN 1(-) of the DWIP-720
Alarm Block Functionality
Preset Positions must be configured for the Alarm Block
features through the software. When an Alarm is detected,
the camera will enter in the default Alarm position. To change
this default Alarm position you must first set the camera’s
position, click “Set Preset Position” in the software and
choose the Alarm Block. There are a total of 8 preset
postitions that can be created for the Alarm Block.
1. Click settings in the upper left screen.
2. In the Local Alarm Alerts Tab, check “Local
Alarm record”, and check “local Alarm
capture”. Set the times for each.
3. Click OK. Set the Motion recording the
same way in the previous step for SD Motion
recording set up.
4. Files can be viewed in the Playback option in
the upper left.
PROGRAM FUNCTIONS
ALARMS
Alarm Setup on PC
Alarm Setup on PC:
1 2 3 4
-- - -+ + ++
1. ALARM OUT -
2. ALARM OUT +
3. ALARM IN +
4. ALARM IN -
ALARM
IP CAMERA
SENSOR
NC: NORMALLY CLOSED
NO: NORMALLY OPEN
NO
GND
5vdc 300 MA MAX
Alarm Connections